Get a complete and extended check out of your anatomical composition by means of panoramic imaging coupled with velocity sign and ahead/backward scan capability creating scanning much simpler, smoother plus more controllable.
one.2.two Warning Labels Warning Labels That means Please carefully read through this guide just before use machine. The following labels can be a. Usually do not location the system over a sloped area. Normally the available if the procedure unit may well slide, leading to particular harm or perhaps the machine functions With all the cellular malfunction.
Usually do not use any cables aside from the cables offered Along with the unit by Mindray. 3. Make use of the cable provided with This technique to attach the printer. Other cables could end in electrical shock. Site fifteen: Mechanical Safety
The consumer will not be permitted to open the addresses and panel in the program, neither Notice: machine disassemble is allowed. To make sure the system efficiency and safety, only Mindray engineers or engineers approved by Mindray can complete upkeep.
Permits usage of multiple scanned angles to type one graphic, resulting in Improved distinction resolution and enhanced visualization
Slash off cable ties connecting the principle unit to the Display screen by diagonal reducing pliers, and afterwards pull out the corresponding cable plugs.
Vital details about our partnership with you: Consumer Romantic relationship Summaries Our Customer Connection Summaries give you a short summary of our companies, costs and obligations whenever we get the job done with you in a broker-dealer or an expense advisory connection.
S. have to deliver the Division using an electronic mail tackle if they've a single. The e-mail furnished could be useful for official communication with the licensee. Nonetheless electronic mail addresses are public history. If you do not wish to provide a private address, be sure to deliver the Division with the e mail address which may be made available to the public. To find out In case you are a licensee under Chapter 455, F.S., be sure to Simply click here . Item Acceptance Accepts:
This guide may referring to information and facts protected by copyright or patents and will not convey any license underneath the patent rights or copyright of Mindray, or of Many others. Site 9: Statement
The chapter provides the method to confirm main purpose and performance of item. This can be only used for reference, not preventive execution. Functionality examining and tests of the aspect shall be performed by Mindray service engineers as well as user collectively. Website page sixty six: Standard Test
Notice: On the keep an eye on, the brightness adjustment will come just before contrast. Just after readjusting the check’s contrast and brightness, modify all preset and peripheral options.
Most four instances tasking for one particular transmitted beam, resulting in superb time resolution and higher body level.
Immediately after changing the CPU module, important file have to be produced Yet again according to the new MAC address and composed into HDD with the equipment. Or else, the configuration function from the merchandise is going to be misplaced. Following taking away the CPU module, Take away panhead Dp50rb screws with washers (twelve M3X6) mounted on the primary unit box, you may take from the board. Website page 118 Figure eight-29 Disassemble the User interface Assembly (1) Hold the higher edge of user interface assembly, and open up up the control panel. Determine eight-thirty Disassemble the Control Panel Assembly (2) Right after eliminating just one countersunk head self-tapping screw PT3X10 fastened about the user interface and just take out the plug on the keyboard and the primary unit connecting cables, you might get rid of the control panel assembly.
Overall performance Check 5.five.one Check Process Resolution Detection depth Geometric Place Accuracy Blackout space examination History the exam visuals five.5.2 Examination Content material The picture used here is just for reference, keep on with the image result in the actual Take note: situation. Demands: Display screen: established the distinction and brightness in the scientific software value (or maybe the default position) Procedure atmosphere: dim room, simulating the clinical application natural environment. Webpage 76 In issue that the transverse resolution screening targets are horizontally displayed, file the minimum distance of two targets that could be clearly acknowledged. Repeat the operation over with the transverse resolution tests targets at other depths. As demonstrated in figure under. Axial resolution ... Webpage seventy seven When using the convex probe, keep the transverse resolution screening targets to notice: be exhibited close to the midline. When utilizing a linear probe with steer purpose, do not turn on the steer functionality when accomplish the transverse resolution test. Zoom inside the area wherever the targets Found if necessary. The diameter from the focus on point at a specific depth is equal for the transverse resolution within the depth. Webpage seventy eight five.
Mindray respects your privateness. We use cookies for many different uses, like Web page functionality, bettering your experience of our website, building integration with social websites and aiding target our advertising.
5.two.3 Geometric positioning precision Longitudinal geometric positioning accuracy Exam Action: Do adjustments as the way in which in tests the utmost depth. History the gap by 20mm Each and every phase to the longitudinal targets line using the measurement caliper; Find the value with the best mistake (to 20mm), compute the precision using the components under The measurement caliper ought to be positioned at the upper edge of the concentrate on, Be aware:... Web site 79 Transverse geometric positioning accuracy Exam Stage: Address the scan surface area of your phantom with water or couple gel, gently Call the probe With all the scan floor Regulate the depth, producing the transverse targets being exhibited within the picture. Change the main focus issue to be posited beside the transverse targets (the normal will not be clear) Adjust parameters like gain, TGC, producing Every single transverse targets being Plainly displayed. Webpage eighty 5.5.two.4 Blackout Space Exam Action: Protect the scan surface area from the phantom with h2o or few gel, Carefully Get hold of the probe Along with the scan surface area Adjust the depth in a reduced value, and set the main target at the closest place to the scan floor. Reduce the worth of parameters like AP, Obtain till the history noise just is often observed. Web site 81: Program Improve And Servicing